    Cascading Switches

    Cascading Switches

    --------------------------------------------------------------------------------

    To add LNB's or receivers, we can cascade switches with LNB's

    A cascade is done when one switch is connected to another switch... That's a cascade... Each cascade will double the downstream options... so by adding 2 cascaded switches, that can potentially give you 4 x 2 x 2 = 16 LNB's

    To double up on receivers, you need to use multi switches or trunked DP34/DP44 switches... SW44's and SW64's may also be trunked.. but it's not worth the cost or effort.. switch to DP LNB's and switches if you need more than what the stand-a-lone Legacy SWxx switches offer..

    2x4 Multi switches will also work on Dish Pro LNB's... but only one cable to the 13v input is required...

    eg...

    D!sh SW21 cascaded to a DP34 and/or a DP44 cascaded to a DP Twin LNB

    or a Diseqc cascaded to an SW22, then to the LNB's



    Some of the proven cascade sequences are:


    Dishpro LNB's


    any DP LNB -> DP34/DP44/DP33/Diseqc -> D!sh SW21 -> Ecoda EC2111 SW22 -> STB

    DP Twin LNB -> diseqc -> STB ( not a true cascade as the Diseqc will overrule the built-in switch of the DP Twin)

    DP Twin LNB -> (both sides) Ecoda EC2111 SW22 -> STB

    DP Twin LNB -> (both sides) EMP-Centauri Profi Line P.162-IW SW22 ( NEW ) -> STB

    DPP Twin -> DP Plus Separator -> DPP IRD/STB (currently, for FTA, a DP Plus Separator (DPPS) works with only with a Sonicview 360 Elite)

    DPP Twin -> DP44 -> DP Plus Separator -> DPP IRD/STB (currently, for FTA, a DPPS works with only with a Sonicview 360 Elite)

    any DP LNB (non-DPP LNB) -> DP33 -> DP Plus Separator -> DPP IRD/STB (currently, for FTA, a DPPS works with only with a Sonicview 360 Elite)

    DP Twin LNB -> D!sh SW21 -> STB


    Legacy LNB's


    Legacy Twin LNB -> D!sh SW21 -> IRD/STB (may only be used on an STB that has a Legacy Twin LNB as an LNB choice in setup)

    Legacy Twin LNB -> Ecoda EC2111 SW22 -> STB

    Legacy Twin LNB -> Diseqc -> STB

    Legacy LNB -> any Multiswitch -> Diseqc -> STB

    Legacy LNB -> any Multiswitch -> Diseqc -> D!sh SW21 -> STB

    Legacy LNB -> 2 x4 Multiswitch -> any SW22 -> Diseqc -> D!sh SW21 -> STB

    Legacy LNB -> 2 x4 Multiswitch -> Diseqc -> D!sh SW21 -> Ecoda EC2111 SW22 -> STB

    Legacy LNB -> any SW22 -> Diseqc -> STB

    Legacy LNB -> Diseqc -> D!sh SW21 -> STB

    Legacy LNB -> Diseqc -> Ecoda EC2111 SW22 -> STB

    Legacy LNB -> Diseqc -> EMP P.162-IW SW22 -> D!sh SW21 -> STB

    Legacy Twin LNB -> (both sides) EMP-Centauri Profi Line P.162-IW SW22 ( NEW ) -> STB

    Legacy LNB -> SW42 -> D!sh SW21 -> IRD/STB

    Legacy LNB -> SW44 -> Ecoda EC2111 SW22 -> STB

    Legacy LNB -> SW44 -> EMP-Centauri Profi Line P.162-IW SW22 -> STB

    Legacy LNB -> SW44 -> D!sh SW21 -> IRD/STB

    Legacy LNB -> SW64 -> Ecoda EC2111 SW22 -> STB

    Legacy LNB -> SW64 -> EMP-Centauri Profi Line P.162-IW SW22 -> STB

    Legacy LNB -> SW64 -> D!sh SW21 -> IRD/STB


    To join DishPro and Legacy Systems, only the EMP-Centauri Profi Line P.162-IW or the Ecoda EC2111 SW22 may be used in the cascade (no other SW22's will work in these examples)

    Any DPP LNB -> SW22 <- SW21 <- Legacy LNB

    Any DPP LNB -> DP44 -> SW22 <- SW21 <- Legacy LNB

    Any DPP LNB -> DP44 -> SW22 <- SW44 <- Legacy LNB

    Any DishPro LNB -> DP34 -> SW21 ->SW22 <- SW64 <- Legacy LNB

    Any DishPro LNB -> DP44 -> SW21 ->SW22 <- SW64 <- Legacy LNB

    Any DishPro LNB -> DP44 -> SW22 <- SW44 <- Legacy LNB

    Any DishPro LNB -> DP44 -> SW22 <- SW64 <- Legacy LNB

    Any DishPro LNB -> DP34 -> SW22 <- SW44 <- Legacy LNB

    Any DishPro LNB -> DP34 -> SW22 <- SW64 <- Legacy LNB



    the above are just some of the many examples... all the various combo's are much too numerous to include here... but hopefully, you get the picture...


    Note:

    All DPP LNB's are multi satellite LNB's, either 2 or 3 sats with an optional 3rd or 4th sat respectively.... each DPP LNB has built in switches that allow either 2 or 3 outputs , as is, with no other switches required.

    As far as DishPro or DishPro Plus Twin LNB's go... 2 cables, one for each sat (port 1 & 2), must be connected to any Diseqc/DP switch...

    The various 3 sat DPP LNB's require 3 cables to a diseqc/DP44 switch, one cable for each sat... The additional sat input on any DPP LNB is then disabled.

    The DP34/44 switches will NOT pass any other switch commands to an LNB, but they may be preceded by any other switch(s) that will pass diseqc commands... ie a D!sh SW21.... and/or an Ecoda EC2111 SW22, both sides... or a Chieta WD2001 SW22, but on the 0KHz/OFF side only.

    Legacy Twins only require 1 cable for both sats when connected to a regular diseqc switch, as a regular Diseqc switch will pass SW21 commands...

    The Default pass thru port for an SW21 is Dish 1 and for an SW22, it's the 0KHz/OFF side.. What this means is that if no switch settings are selected.. The LNB signal, as sensed by the STB, will be one that is connected to the default ports.

    Auto setup STB's will usually only see the default port sides of any cascaded switch setup... ie they will see a DP44's 4 diseqc ports for a DP44 on the default Dish 1 side of an SW21... but will not pick up a DP44 that is connected to the SW21's Dish 2 port... that then has to be added manually in setup.


    Images: From top Left to Right...

    SW21 old style
    SW42
    SW44
    SW64
    SW21 coax lengths
    SW21 new style
    3x4 Multiswitch - Zinwell
    4x4 Multiswitch - Channel Master 69041FD
    3x4 Multiswitch - EMP-Centauri 134-A
    5x4 Multiswitch - EMP-Centauri 140-A
    4x4 Multiswitch - B3V
    4x1 Diseqc
    SW22 - Ecoda EC2111
    Sw22 - Chieta WS2001
    SW22 - EMP-Centauri P.162-IW
    8x2 Diseqc - EMP-Centauri P.167-W
    DP34
    DP44
    DP44 power supply
    Dish Pro Power Inserter
    Dish Pro Plus Separator (DPPS)







































    Last edited by WIZZARD; 02-22-09 at 01:31 PM.
    .











    To become a VIP Member please click this Link
    VIP MEMBERSHIP
    READ FORUM RULES HERE : Rules

    Welcome to Computer & Consumer Electronics..AKA Pete's or (PBP)...Enjoy your stay here with us...

    The information contained in any of my posts relating to DSS satellite reception is information that I have gathered from publicly sources under the same protections of Free Speech governed under the Laws of the U.S. is for information use only.The distribution of said information is considered a form of free speech. I do not advocate the illegal use of
    such information under the U.S. Laws.

Similar Threads

  1. FTA ALL IN ONE GUIDE.pdf ,DN LNB and Switches.pdf
    By WIZZARD in forum General FTA Discussions
    Replies: 0
    Last Post: 01-31-09, 04:56 PM
  2. Antenna Settings Twin and Dual LNB's with Dish 21 switches
    By srameram in forum CaptiveWorks Discussions
    Replies: 0
    Last Post: 10-22-08, 08:32 PM

Visitors found this page by searching for:

cascading of switches

casacding switches

cascading switches and multiswitches-google

cascading dp-44 and dp-34 switches

rules for cascading switches

cascading sw44

multiswitch cascadingsw21 Dish legacy DPP receiver

Tags for this Thread

Bookmarks

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts